• Users Online: 64
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2016  |  Volume : 21  |  Issue : 2  |  Page : 80-87

Inter-rater and intra-rater reliability of Kinovea software for measurement of shoulder range of motion


1 Department of Basic Science, Faculty of Physical Therapy, Cairo University, Giza, Egypt
2 Department of Orthopedics, Faculty of Physical Therapy, 6th Octobre University, Cairo, Egypt

Correspondence Address:
Eman A Embaby
2108, Street Arqam, Merag City, Maadi, Cairo, 11931
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1110-6611.196778

Rights and Permissions

Background Goniometry is a tool used frequently for measuring and documenting range of motion (ROM) during a physical therapy examination. With modern innovations in technology, new methods other than the universal goniometer have been applied. Kinovea software is a recent video-based method that uses a virtual goniometer to obtain values for the ROM of joints. However, the software’s reliability in measuring shoulder joint ROM has not been studied. Purpose This study was conducted to investigate the inter-rater and intrarater reliability of Kinovea software for measuring shoulder joint ROM in healthy individuals. Materials and methods Shoulder joint ROM was measured in 52 healthy individuals (mean±SD age was 26.7±4.2 years) using Kinovea photographic measurements by three trained raters. Intrarater reliability was examined by a single rater within the same day. Shoulder flexion, abduction, and external and internal rotation ROM were measured with the patient in supine position. Results The inter-rater reliability ranged from an intraclass correlation coefficient value of 0.95 to 0.98, whereas the intrarater reliability ranged from an intraclass correlation coefficient value of 0.98 to 0.99. Conclusion This study showed highly reliable shoulder joint ROM measurements in healthy adults using the Kinovea software.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed759    
    Printed6    
    Emailed0    
    PDF Downloaded149    
    Comments [Add]    

Recommend this journal